The house, comprising two flats and an extension dating from 1980, has a high heat loss of 32.5 kW and an annual energy consumption of between 21 and 29 MWh. Instead of extensive insulation or installing a heat pump, the owner decided to reduce costs in a different way – the aim was to lower the unit cost of energy whilst retaining the existing electric radiant heating system.
Summary data on electricity consumption and costs from previous years are available:
| Period | NT consumption (kWh) |
Summer consumption (kWh) |
Total consumption (kWh) |
Total payment (CZK) |
Unit price (CZK/kWh) |
|---|---|---|---|---|---|
| 2016/2017 | 20,390 | 714 | 21,104 | 57,384 | 2.72 |
| 2017/2018 | 23,824 | 1,262 | 25,086 | 68,747 | 2.74 |
| 2018/2019 | 22,760 | 1,674 | 24,434 | 73,232 | 2.99 |
| 2019/2020 | 20,931 | 1,170 | 22,101 | 77,069 | 3.48 |
| 2020/2021 | 26,526 | 2,590 | 29,116 | 93,306 | 3.20 |
| 2021/2022 | 25,346 | 1,027 | 26,373 | 116,848 | 4.43 |
| 2022/2023 *) | 21,120 | 3,963 | 25,083 | 156,340 | 6.23 |
| 2024 | SPOT – NT/VT not monitored | 26,984 | 78,646 | 2.91 | |
| 2025 | SPOT – NT/VT not monitored | 30,273 | 84,794 | 2.80 | |
*) Amount of energy consumed affected by the commissioning of the PV system
From January 2024, the property switched to a system of buying and selling electricity at spot prices (optimised by an algorithm within the HES storage system); more detailed monthly statements have been available since then:
| Period | Total consumption (kWh) |
Off-take from the grid (kWh) |
PV system generation (kWh) |
Feed-in to the grid (kWh) |
Consumption from the grid (CZK) |
Feed-in to the grid (CZK) |
Electricity costs (CZK) |
Achieved price (CZK/kWh) |
|---|---|---|---|---|---|---|---|---|
| 01/2024 | 4,442 | 3,827 | 756 | 141 | 17,763 | 216 | 16,947 | 3.82 |
| 02/2024 | 3,283 | 2,678 | 722 | 117 | 11,354 | 122 | 11,232 | 3.42 |
| 03/2024 | 2,798 | 1,438 | 1,815 | 455 | 6,346 | 405 | 5,941 | 2.12 |
| 04/2024 | 2,069 | 556 | 2,248 | 735 | 3,116 | 364 | 2,752 | 1.33 |
| 05/2024 | 1,000 | 85 | 2,053 | 1,138 | 1,230 | 1,417 | -187 | -0.18 |
| 06/2024 | 649 | 226 | 1,030*) | 607 | 1,719 | 1,654 | 65 | 0.1 |
| 07/2024 | 657 | 129 | 1,200*) | 672 | 1,364 | 1,783 | -419 | -0.63 |
| 08/2024 | 1,100 | 98 | 2,954 | 1,952 | 1,382 | 3,681 | -2,299 | -2.09 |
| 09/2024 | 1,039 | 164 | 2,204 | 1,329 | 1,570 | 2,422 | -852 | -0.82 |
| 10/2024 | 1,962 | 1,066 | 1,273 | 377 | 5,661 | 640 | 5,021 | 2.56 |
| 11/2024 | 3,234 | 2,731 | 656 | 153 | 16,365 | 623 | 15,742 | 4.87 |
| 12/2024 | 4,751 | 4,210 | 591 | 50 | 24,328 | 225 | 24,103 | 5.07 |
| Total | 26,984 | 17,208 | 17,502 | 7,726 | 92,198 | 13,552 | 78,646 | 2.91 |
*) External inverter with 10 kWp PV system switched off
Prices include VAT.
The results for 2024 show that a PV system with HES battery storage, effectively managed in line with spot price trends, is capable of achieving average prices corresponding to those seen in 2016/2017.
| Period | Total consumption (kWh) |
Off-take from the grid (kWh) |
PV system generation (kWh) |
Feed-in to the grid (kWh) |
Consumption from the grid (CZK) |
Feed-in to the grid (CZK) |
Electricity costs (CZK) |
Achieved price (CZK/kWh) |
|---|---|---|---|---|---|---|---|---|
| 01/2025 | 4,385 | 3,821 | 622 | 58 | 20,731 | 228 | 20,503 | 4.68 |
| 02/2025 | 4,378 | 3,201 | 1,374 | 197 | 18,407 | 419 | 17,988 | 4.10 |
| 03/2025 | 3,509 | 1,708 | 2,388 | 587 | 8,983 | 579 | 8,404 | 2.39 |
| 04/2025 | 2,058 | 659 | 2,243 | 844 | 3,492 | 840 | 2,652 | 1.28 |
| 05/2025 | 1,439 | 144 | 2,504 | 1,209 | 1,542 | 1,444 | 98 | 0.07 |
| 06/2025 | 1,027 | 70 | 2,444 | 1,487 | 1,346 | 2,772 | -1,426 | -1.38 |
| 07/2025 | 1,026 | 83 | 2,413 | 1,470 | 1,404 | 2,889 | - 1,485 | -1.44 |
| 08/2025 | 1,064 | 105 | 2,876 | 1,917 | 1,354 | 2,603 | -1,249 | -1.17 |
| 09/2025 | 1,043 | 254 | 1,912 | 1,123 | 2,012 | 2,612 | -600 | -0.58 |
| 10/2025 | 2,366 | 1,493 | 1,266 | 393 | 6,875 | 988 | 5,887 | 2.49 |
| 11/2025 | 3,528 | 2,885 | 741 | 98 | 14,910 | 166 | 14,744 | 4.18 |
| 12/2025 | 4,450 | 3,955 | 537 | 42 | 19,358 | 79 | 19,279 | 4.33 |
| Total | 30,273 | 18,378 | 21,319 | 9,424 | 100,412 | 15,618 | 84,794 | 2.80 |
In 2025, too, very good operational results were achieved thanks to the PV system and optimised management of the HES storage facility, despite the house’s increasing energy consumption.
| Period | Total consumption (kWh) |
Off-take from the grid (kWh) |
PV system generation (kWh) |
Feed-in to the grid (kWh) |
Consumption from the grid (CZK) |
Feed-in to the grid (CZK) |
Electricity costs (CZK) |
Achieved price (CZK/kWh) |
|---|---|---|---|---|---|---|---|---|
| 01/2026 | 5,072 | 4,654 | 472 | 54 | 21,797 | 152 | 21,645 | 4.27 |
| 02/2026 | 3,987 | 3,379 | 724 | 116 | 14,184 | 172 | 14,012 | 3.51 |
| 03/2026 | 2,969 | 1,374 | 2,393 | 798 | 6,216 | 1,184 | 5,032 | 1.69 |
| 04/2026 | 2,231 | 875 | 2,018 | 662 | 3,077 | 713 | 2,364 | 1.06 |
| 05/2026 | 1,355 | 350 | 2,035 | 1,030 | 1,483 | 2,484 | -1,001 | -0.74 |
| 06/2026 | 981 | 189 | 2 343 | 1 551 | 1 656 | 4 472 | -2 816 | -2,87 |
| 07/2026 | 1 022 | 241 | 2 425 | 1 644 | 1 834 | 4 077 | -2 243 | -2,19 |
| 08/2026 | 1 070 | 159 | 2 687 | 1 776 | 1 715 | 5 307 | -3 592 | -3,36 |
| 09/2026 | - | - | - | - | - | - | - | - |
| 10/2026 | - | - | - | - | - | - | - | - |
| 11/2026 | - | - | - | - | - | - | - | - |
| 12/2026 | - | - | - | - | - | - | - | - |
| Total | 18 687 | 11 121 | 15 097 | 7 631 | 51 962 | 18 561 | 33 401 | 1,79 |
The owner has retained the tried-and-tested electric radiant heating system and supplemented it with a photovoltaic power plant and HES battery storage. The house is fitted with a combination of ECOSUN radiant panels, ECOFILM floor and ceiling foils, ECOFLOOR heating cables and mats, and ECOFLEX convectors. The total installed power of the electric heating system is 29.2 kW.